ESOS Helpline
Type:20151122173020
Material :cast iron.stainless steel
Inet diameter:Max 300mm
Outlet diameter:Max 300mm
Flow:Max 800m³/h
Operating temperature:<=80°
Solid particles:Max 180mm
Work permit pressure:<=5.5bar
Allow experimental pressure:<=5.5bar
An overview of the
ZW series self-priming non-clogging sewage pump is a kind of new structure product which has been successfully developed on the basis of repeatedly studying the similar technology at home and abroad.
The self-priming pump set and non-clogged sewage into an organic whole, the axial back mixing type, and through the unique design of the pump body, impeller flow channel can be like general self-priming centrifugal pump, do not need to install the bottom valve and irrigation water diversion, and inhale row contains larger particles liquid, solid and long fiber impurities can be widely used in municipal drainage project, studied the breeding, light industry, papermaking, textile, food, chemical, electric power, chemical media such as fiber, paste and mixed suspension is the most ideal impurity pump.
Compared with similar domestic products, this pump has the characteristics of simple structure, good self-absorption performance, strong sewage discharge capacity, high efficiency and energy saving, easy to use and maintenance, etc., which is the first of its kind in China.Each technical performance index occupies the domestic leading position, achieves the international advanced level, has the broad application market and the development prospect.
Preparation and operation before starting
1. Check whether the fasteners of pump base, coupling, bearing seat and other connecting parts are loose or not.If there is looseness, tighten it.
2. Whether the coupling is stuck or abnormal sound or not when rotating by hand
3. Open the water inlet valve above the pump, add no less than two-thirds of the volume of the pump body, and close the valve.After starting up no need to refill water.
4. Connect the power supply and try to turn it clockwise from the motor end.(no reversal is allowed)
5. Turn on the machine and observe whether the pump is running normally.If there is any abnormal phenomenon, the reason should be found out and eliminated.
Using range
1, the environment temperature 50 ℃, medium temperature s80 ℃, the special requirements of up to 200 ℃.
2. The PH value of the medium is 6-9 for cast iron and 2-13 for stainless steel.
3. The medium weight shall not exceed 1240kg/m..
4. The height of self-suction shall not exceed the specified value of 4.5-5.5 meters, and the total length of the suction pipe shall be less than 10 meters.5. The diameter of suspended particles passing through the capacity is 60% of the diameter of the pump, and the fiber length is 5 times the diameter of the pump.
Model specification:
ZW -80-40-16 P B
ZW--Self-priming non-blocking sewage pump
80--Inlet diameter (mm)
40--Rated flow rate (m³/h)
16--Rated head (m)
P--Stainless steel (cast iron if not marked)
B--Explosion-proof motor (ordinary motor without standard)
Model and performance parameters
You are welcome to consult at any time