Attention to the installation of pneumatic diaphragm pump

Release time:2018/07/13source:China pump networkTimes of browsing:673

Matters needing attention in installation of pneumatic diaphragm pump, installation drawing of pneumatic diaphragm pump

1. Attention to the installation of pneumatic diaphragm pump

In the process of installation and use of pneumatic diaphragm pump, many pneumatic diaphragm pumps install attention to the user without knowing clearly on the installation, resulting in a series of problems, such as pneumatic diaphragm pump, such as

Pneumatic diaphragm pump no water, pneumatic diaphragm pump easy to damage, and so on, the following points about the installation of pneumatic diaphragm pump for your reference:

1, try to make the pump and the pump close to the better, so that the length of the suction pipe is controlled within 5 meters the best, import pipe elbow control in 1 is appropriate.

2. If a hard pipe is used to transport the liquid, there should be a hose between the pneumatic diaphragm pump and the hard pipe as a connection between the pump and the hard pipe. The hose is equivalent to the soft joint so that the whole system can be reduced.

Vibration and easy disassembly and maintenance of pneumatic diaphragm pump, if you want to make pneumatic diaphragm pump no vibration phenomenon, it is suggested to install damper in the outlet, in order to further reduce the vibration phenomenon in the liquid flow of the outlet pipe.

3. Before the gas supply system enters the pump valve valve, it is necessary to install an air filter, the pressurizer to filter the air and stabilize the pressure. It is best to add one more air dryer.

The water in the gas source.

4. When the pneumatic diaphragm pump is connected with other equipment, the position of the fluid storage tank of the equipment itself is much higher than the installation position of the pump. Please note that the outlet pipe must be installed one.

When the pump is completely closed, the outlet valve should be completely closed when the pump is stopped, so as to avoid possible damage to the pump due to the outlet pressure. Because the role of the outlet pipe back pressure after shutdown will lead to

The diaphragm is in the state of being squeezed for a long time, resulting in the reduction of the life of the diaphragm. It is even possible that the diaphragm will be damaged due to back pressure when it is shut down, resulting in leakage of liquid from the valve.

Come on. If the exit pressure is more than 0.3Bar, we have to install the valve at the outlet. We recommend that the best way is to install a shut-off valve on the inlet pipe to reduce the back pressure to the diaphragm.

Damage.

Two. The installation diagram of the pneumatic diaphragm pump is as follows

The detailed introduction of diaphragm pump can be checked on the product specification page of pneumatic diaphragm pump.

The technical notes for installation of pneumatic diaphragm pump and installation drawings of pneumatic diaphragm pump are provided by Zhejiang Ou Sen Pump Co., Ltd